The appliance has been tested before being
put into service. The information provided
below is intended to assist in the identifi cation
and correction of any anomalies and malfun-
ctions which might occur during use.
The user can solve some of these problems
himself, but for others specifi c technical
knowledge or skill is required, and so they
must only be carried out by qualifi ed staff with
recognised experience acquired in the specifi c
sector of operation.
Faults
Smell of gas.
The pilot light does not
ignite.
The pilot light goes out.
The pilot light ignites but
the burner remains off .
The fl ame is yellow.
GB
The appliance does not heat
up.
The control panel does not
come on.
3301390_ut_GB_rev.1

FAULT

TROUBLESHOOTING

For all requirements contact the agents or
the headquarters of Angelo Po which can be
found in the contacts section of the website
http://www.angelopo.com.
Causes
Occasional leak because
fl ame has gone out.
Air in pipelines due to long
period out of use.
The thermocouple has not
warmed up enough.
Burner dirty, heat exchange
pipes clogged, condensation
drips.
Contactor not receiving
power or faulty.
Electronic circuit board not
receiving electrical power.
- 18 -
Important
Remedies
Turn off the gas supply tap and
ventilate the room.
Make more attempts to light the
fl ame.
Make more attempts to light the
fl ame.
Check the condition of the ther-
mostat and activate any ignition
enabling device.
Important
Contact the after-sales service.
Check the condition of the ther-
mostat and activate any ignition
enabling device.
Check or replace the contactor coil.
Check or swap the phase wire
connections.