Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
OPERATING­INSTRUCTIONS­AND­OWNER'S­MANUAL
READ INSTRUCTIONS CAREFULLY:­Read­and­follow­all­instructions.­Place­instructions­in­a­safe­place­for­
future­reference.­Do­not­allow­anyone­who­has­not­read­these­instructions­to­assemble,­light,­adjust­or­
operate­the­heater.
LANGUAGES INCLUDED:
•­ ENGLISH
•­ FRENCH
•­ SPANISH
If the information in this manual is not followed exactly, a fire or explosion
WARNING:
may result causing property damage, personal injury or loss of life.
­ — ­ Do­not­store­or­use­gasoline­or­other­flammable­vapors­and­liquids­in­the­vicinity­of­this­or­any­
other­appliance.
—­ An­LP­cylinder­not­connected­for­use­shall­not­be­stored­in­the­vicinity­of­this­or­any­other­
appliance.
—­ WHAT­TO­DO­IF­YOU­SMELL­GAS
­ •­ Do­not­try­to­light­appliance.
­ •­ Extinguish­any­open­flame.
­ •­ Shut­off­gas­to­appliance.
—­ Service­must­be­performed­by­a­qualified­service­agency.
This­is­an­unvented­gas-fired­portable­heater.­It­uses­air­(oxygen)­from­the­area­in­which­it­is­used.­
Adequate­combustion­and­ventilation­air­must­be­provided.­Refer­to­page­3.
FORCED AIR PROPANE
CONSTRUCTION HEATER
Enerco­Group,­Inc.,­4560­W.­160TH­ST.,­CLEVELAND,­OHIO­­44135
Model­#
MH35FA
27401

Publicidad

Tabla de contenido
loading

Resumen de contenidos para HeatStar MH35FA

  • Página 1 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! OPERATING­INSTRUCTIONS­AND­OWNER’S­MANUAL FORCED AIR PROPANE Model­# CONSTRUCTION HEATER MH35FA READ INSTRUCTIONS CAREFULLY:­Read­and­follow­all­instructions.­Place­instructions­in­a­safe­place­for­ future­reference.­Do­not­allow­anyone­who­has­not­read­these­instructions­to­assemble,­light,­adjust­or­ operate­the­heater. LANGUAGES INCLUDED: •­ ENGLISH •­ FRENCH •­...
  • Página 2: Tabla De Contenido

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! WARNING: WARNING: ­ YOUR­SAFETY­IS­IMPORTANT­TO­YOU­AND­TO­OTHERS,­ CARBON MONOXIDE CAN KILL YOU SO­PLEASE­READ­THESE­INSTRUCTIONS­BEFORE­YOU­ ­ NOT­FOR­HOME­OR­RECREATIONAL­VEHICLE­USE,­ OPERATE­THIS­HEATER. USING­A­PORTABLE­HEATER­IN­AN­ENCLOSED­AREA­ CAN­PRODUCE­DEADLY­CARBON­MONOXIDE GENERAL HAZARD WARNING: ­ FAILURE­TO­COMPLY­WITH­THE­PRECAUTIONS­AND­...
  • Página 3: Operating Precautions

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! OPERATING PRECAUTIONS SAFETY PRECAUTIONS This­is­a­propane,­direct-fired,­forced­air­heater.­It's­intended­use­ 1.­ Check­the­heater­thoroughly­for­damage.­DO­NOT­operate­a­ is­primarily­temporary­heating­of­buildings­under­construction,­ damaged­heater. alteration­or­repair. 2.­ DO NOT­modify­the­heater­or­operate­a­heater­which­has­been­ Propane­is­heavier­than­air.­If­propane­leaks­from­a­connection­or­ modified­from­its­original­condition. fitting,­it­sinks­to­the­floor,­collecting­there­with­the­surrounding­ 3.­ Use­only­propane­gas. air,­forming­a­potentially­explosive­mixture.­Obviously,­propane­ 4.­...
  • Página 4: Odor Fade Warning

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! ODOR FADE WARNING ODOR FADING ‑ NO ODOR DETECTED •­Some­people­cannot­smell­well.­Some­people­cannot­smell­ the­odor­of­the­man-made­chemical­added­to­propane­(LP)­ WARNING or­natural­gas.­You­must­determine­if­you­can­smell­the­ Asphyxiation Hazard odorant­in­these­fuel­gases. ­ •­Do­not­use­this­heater­for­heating­human­living­­ ­ •­Learn­to­recognize­the­odor­of­propane­(LP)­gas­and­ ­...
  • Página 5: Maintenance And Storage

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! OPERATING INSTRUCTIONS MAINTENANCE AND STORAGE 1.­ The­heater­should­be­inspected­before­each­use,­and­at­least­ PREPARING FOR OPERATION annually­by­a­qualified­person. 1.­ Check­the­heater­for­possible­shipping­damage.­If­any­is­found,­ 2.­ Before­each­use,­check­the­soft­"O"­ring­seat­at­the­bullnose­ immediately­notify­the­factory. of­the­POL­fitting.­If­the­"O"­ring­is­cut,­scuffed,­or­otherwise­ 2.­ Follow­all­of­the­"Precautions".­ damaged,­replace­it­with­part­number­6681.
  • Página 6 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! Forced Air Propane Construction Heater • Model #35FA REF.# ITEM# DESCRIPTION QTY. REF.# ITEM# DESCRIPTION QTY. ­ 1­ 27406­ Outer­Shell­­ ­ 13­ 28077­ Fan­Blade,­6.75­x­.75­Pitch­ ­ 2­ 27442­...
  • Página 7 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! SIZE AND CAPACITY OF PROPANE BTU'S PER HOUR REQUIRED CYLINDERS REQUIRED The­charts­below­show­the­approximate­size­of­the­cylinder­required­ for­these­heaters.­­To­use­the­chart: 1.­ Select­the­lowest­air­temperature­expected­(at­the­bottom­of­ the­chart). 2.­ Move­straight­up­to­time­of­operation­desired­(left­side­of­ chart). 3.­...
  • Página 8 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! WARNING Air­Quality­Hazard •­Do­not­use­this­heater­for­heating­human­living­quarters.­ •­Use­of­direct-fired­heaters­in­the­construction­environment­can­result­in­exposure­to­levels­of­CO,­CO2,­and­NO2­considered­ to­be­hazardous­to­health­and­potentially­life­threatening.­ •­Do­not­use­in­unventilated­areas.­ •­Know­the­signs­of­CO­and­CO2­poisoning.­ •­Headaches,­stinging­eyes­ •­Dizziness,­disorientation­ •­Difficulty­breathing,­feels­of­being­suffocated­ •­Proper­ventilation­air­exchange­(OSHA­29­CFR­1926.57)­to­support­combustion­and­maintain­acceptable­air­quality­shall­be­ provided­in­accordance­with­OSHA­29­CFR­Part­1926.154,­ANSI­A10.10­Safety­Requirements­for­Temporary­and­Portable­ Space­Heating­Devices­and­Equipment­used­in­the­Construction­Industry­or­the­Natural­Gas­and­Propane­Installation­Codes­ CSA­B149.1.­ •­Periodically­monitor­levels­of­CO,­CO2­and­NO2­existing­at­the­construction­site­–­at­the­minimum­at­the­start­of­the­ shift­and­after­4­hours. •­Provide­ventilation­air­exchange,­either­natural­or­mechanical,­as­required­to­maintain­acceptable­indoor­air­quality. Canada­8-hr­time­weighted­average USA­8-Hr­Time­weighted­average WorkSafe­BC­OHS­Guidelines­Part­5.1 (OSHA­29­CFR­1926.55­App­A) and­Ontario­Workplaces­Reg­833...
  • Página 9 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! THIS PAGE INTENTIONALLY LEFT BLANK ESTA PÁGINA INTENCIONALMENTE SE DEJA EN BLANCO CETTE PAGE A ÉTÉ INTENTIONNELLEMENT LAISSÉE VIERGE Forced Air Propane Construction Heater Operating Instructions and Owner’s Manual...
  • Página 10: Operating Instructions

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! OPERATING INSTRUCTIONS Model­# AND OWNER’S MANUAL MH35FA READ INSTRUCTIONS CAREFULLY:­Read­and­follow­all­instructions.­Place­instructions­in­a­safe­ place­for­future­reference.­Do­not­allow­anyone­who­has­not­read­these­instructions­to­assemble,­ light,­adjust­or­operate­the­heater. WARNING: USE­ONLY­MANUFACTURER’S­REPLACEMENT­PARTS.­USE­OF­ANY­OTHER­PARTS­COULD­ CAUSE­INJURY­OR­DEATH.­REPLACEMENT­PARTS­ARE­ONLY­AVAILABLE­DIRECT­FROM­THE­ FACTORY­AND­MUST­BE­INSTALLED­BY­A­QUALIFIED­SERVICE­AGENCY. PARTS ORDERING INFORMATION: PURCHASING: Accessories­may­be­purchased­at­any­HeatStar­local­dealer­or­direct­...
  • Página 11 NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! GUIDE­D’UTILISATION­ET­MANUEL­DU­PROPRIÉTAIRE APPAREIL DE CHAUFFAGE Modèle­# AU PROPANE À AIR PULSÉ POUR CHANTIER DE CONSTRUCTION MH35FA LISEZ SOIGNEUSEMENT LES INSTRUCTIONS :­Lisez­et­observez­toutes­les­instructions.­Conservez­ces­ instructions­dans­un­endroit­sécuritaire­pour­vous­y­référer­ultérieurement.­Ne­permettez­pas­à­quiconque­ n’ayant­pas­lu­les­présentes­instructions­d’assembler,­d’allumer,­de­régler­ou­de­faire­fonctionner­l'appareil. LANGUES INCLUS: •­ ANGLAIS •­ FRANCAIS •­...
  • Página 12: A Vertissement Général De Danger

    NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! AVERTISSEMENT : AVERTISSEMENT : ­ VOTRE­SÉCURITÉ­EST­IMPORTANTE­POUR­VOUS­ET­POUR­LES­ LE MONOXYDE DE CARBONE PEUT VOUS TUER AUTRES,­PAR­CONSÉQUENT­VEUILLEZ­LIRE­CES­DIRECTIVES­...
  • Página 13: Précautions Liées Au Fonctionnement

    NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! PRÉCAUTIONS LIÉES AU PRÉCAUTIONS LIÉES À LA SÉCURITÉ FONCTIONNEMENT 1.­ Vérifiez­attentivement­si­l'appareil­de­chauffage­a­subi­ des­dommages.­NE­FAITES­PAS­fonctionner­un­appareil­ Cet­appareil­de­chauffage­à­air­pulsé­et­à­feu­direct­fonctionne­au­gaz­ endommagé. propane.­Il­est­destiné­principalement­à­chauffer­temporairement­des­ 2.­ NE MODIFIEZ PAS­l'appareil­de­chauffage­et­ne­le­faites­pas­ édifices­en­construction,­en­rénovation­ou­en­réparation.
  • Página 14: Avertissement Lié Aux Substances Odorantes

    NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! AVERTISSEMENT LIÉ AUX SUBSTANCES SUBSTANCE ODORANTE AUCUNE ODORANTES ODEUR DÉCELÉE •­Certaines­personnes­ne­détectent­pas­bien­les­odeurs.­Il­est­donc­ AVERTISSEMENT possible­que­certaines­personnes­ne­puissent­sentir­la­substance­ odorante­ajoutée­au­gaz­propane­(liquéfié)­ou­au­gaz­naturel.­ Risque d'asphyxie Vous­devez­savoir­si­vous­arrivez­à­déceler­l'odeur­de­cette­...
  • Página 15: Instructions De Fonctionnement

    NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! INSTRUCTIONS DE FONCTIONNEMENT ENTRETIEN ET ENTREPOSAGE AVANT LE FONCTIONNEMENT 1.­ L'appareil­de­chauffage­doit­être­vérifié­avant­chaque­utilisation­ et­au­moins­une­fois­par­année­par­un­technicien­qualifié.
  • Página 16 NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! Appareil de chauffage au propane à air pulsé pour chantier de construction • Modèle # 35FA RÉF.# ART. # DESCRIPTION QTÉ RÉF. # ART. # DESCRIPTION QTÉ...
  • Página 17: Tableau­DE­DImensions­ET­COntenances

    NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! TABLEAU DE DIMENSIONS ET BTU PAR HEURE REQUIS CONTENANCES DES BONBONNES NOMBRE DE BTU REQUISES PAR HEURE DE GAZ PROPANE REQUISES Pieds cubes...
  • Página 18 NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! AVERTISSEMENT Danger­de­la­qualité­de­l’air •­N’utilisez­pas­cet­appareil­de­chauffage­pour­le­chauffage­des­locaux­d’habitation­humaine. •­L’utilisation­des­appareils­de­chauffage­direct­dans­les­environnements­de­construction­peut­vous­exposer­à­des­niveaux­de­ CO,­CO2,­et­NO2,­qui­sont­considérés­comme­dangereux­pour­la­santé­et­potentiellement­mortels.­ •­Ne­pas­utiliser­dans­les­zones­non­ventilées.­ •­Connaissez­les­signes­d’empoisonnement­au­CO­et­CO2.­ •­Maux­de­tête,­brûlure­des­yeux­ •­Vertige,­désorientation­ •­Difficulté­à­respirer,­sensation­d’étouffement­ •­Un­échange­d’air­de­ventilation­adéquat­(OSHA­29­CFR­1926.57)­pour­supporter­la­combustion­et­maintenir­une­qualité­...
  • Página 19: Modèle

    NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! NE JAMAIS LAISSER LE CHAUFFAGE SANS SURVEILLANCE PENDANT LE BRÛLAGE! GUIDE D’UTILISATION ET Modèle­# MANUEL DU PROPRIÉTAIRE MH35FA LISEZ SOIGNEUSEMENT LES INSTRUCTIONS :­Lisez­et­observez­toutes­les­instructions.­Conservez­ces­ instructions­dans­un­endroit­sécuritaire­pour­vous­y­référer­ultérieurement.­Ne­permettez­pas­à­quiconque­ n’ayant­pas­lu­les­présentes­instructions­d’assembler,­d’allumer,­de­régler­ou­de­faire­fonctionner­l'appareil. AVERTISSEMENT : N'UTILISEZ­QUE­LES­PIÈCES­DE­REMPLACEMENT­DU­FABRICANT.­L'UTILISATION­...
  • Página 20: Calentador De Propanoa Aire Forzado Para Construcción

    ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! INSTRUCCIONES­DE­USO­Y­MANUAL­DEL­USUARIO CALENTADOR DE PROPANO Modelo­# A AIRE FORZADO PARA CONSTRUCCIÓN MH35FA LEA CUIDADOSAMENTE LAS INSTRUCCIONES: lea­y­siga­todas­las­instrucciones.­Consérvelas­en­ un­lugar­seguro­para­futura­referencia.­No­permita­que­nadie­que­no­haya­leído­estas­instrucciones­ arme,­encienda,­ajuste­o­use­el­calentador. IDIOMAS INCLUIDO: •­ INGLÉS­ •­ FRANCÉS •­...
  • Página 21: Advertencia General De Peligro

    ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ADVERTENCIA: ADVERTENCIA: ­ SU­SEGURIDAD­ES­IMPORTANTE­PARA­USTED­Y­PARA­LOS­ EL MONOXIDO DE CARBONO PUEDE MATARLO DEMÁS.­POR­ELLO,­LEA­ESTAS­INSTRUCCIONES­ANTES­DE­ ­ NO­PARA­EL­USO­CASERO­O­RECREATIVO­DE­VEHÍCULOS,­ UTILIZAR­EL­CALENTADOR.­ USANDO­UN­CALENTADOR­PORTÁTIL­EN­UN­ÁREA­CERRADA­ PUEDE­PRODUCIR­MONÓXIDO­DE­CARBONO­MORTAL ADVERTENCIA GENERAL DE PELIGRO: ADVERTENCIA:...
  • Página 22: Precauciones De Utilización

    ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! PRECAUCIONES DE UTILIZACIÓN PRECAUCIONES DE SEGURIDAD Este­artefacto­es­un­calentador­de­propano­de­caldeo­directo­a­aire­ 1.­ Revise­cuidadosamente­si­el­calentador­presenta­daños.­NO­use­ forzado.­Está­diseñado­principalmente­para­calefaccionar­edificios­en­ un­calentador­dañado.­ construcción,­remodelación­o­reparación. 2.­ NO modifique­el­calentador­ni­lo­use­si­su­configuración­original­ ha­sido­modificada. El­propano­es­más­pesado­que­el­aire.­Cuando­el­propano­escapa­ 3.­ Utilice­únicamente­gas­propano. de­una­conexión­o­acople,­desciende­hacia­el­piso­y­se­acumula­...
  • Página 23: Advertencia De Disipación Del Olor

    ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ADVERTENCIA DE DISIPACIÓN DEL OLOR DISIPACIÓN DEL OLOR‑ NO SE DETECTA NINGÚN OLOR ADVERTENCIA •­Algunas­personas­tienen­problemas­de­olfato.­Algunos­no­pueden­ detectar­el­olor­del­químico­artificial­-añadido­al­propano­(LP)­o­ Peligro de asfixia al­gas­natural.­Debe­determinar­si­es­capaz­de­oler­la­sustancia­ ­ •­ ­ N o­utilice­este­calentador­para­calefaccionar­locales­ aromática­que­contienen­estos­gases­combustibles. habitados­por­personas.
  • Página 24: Mantenimiento Y Almacenamiento

    ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! INSTRUCCIONES DE USO MANTENIMIENTO Y ALMACENAMIENTO 1.­ Debe­inspeccionar­el­calentador­antes­de­cada­uso­y­hacerlo­ PREPARATIVOS PARA EL USO revisar­por­una­persona­calificada­una­vez­por­año. 1.­ Revise­el­calentador­para­determinar­si­sufrió­daños­durante­el­envío.­Si­ 2.­ Antes­de­cada­uso,­revise­siempre­el­asiento­del­anillo­“O”­de­ encontrara­alguno,­notifíquelo­inmediatamente­a­la­fábrica.
  • Página 25 ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! Calentador de propano a aire forzado para construcción • Modelo # 35FA # DE # DE # REF. DESCRIPCIÓN CANTIDAD # REF. DESCRIPCIÓN CANTIDAD ARTÍCULO ARTÍCULO 27406 Juego­de­la­estructura­del­calentador 28077 Aspas­del­ventilador,­6,75­x­0,75­...
  • Página 26 ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! TAMAÑO Y CAPACIDAD DE LOS REQUISITOS DE BTU POR HORA CILINDROS DE PROPANO NECESARIOS REQUISITOS DE BTU POR HORA Los­gráficos­siguientes­muestran­el­tamaño­aproximado­del­cilindro­ Volumen del Incremento de temperatura requerido (°...
  • Página 27 ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ADVERTENCIA Peligro­para­la­calidad­del­aire •­No­utilice­este­calefactor­para­calentar­viviendas­de­personas.­ •­El­uso­de­calefactores­a­fuego­directo­en­lugares­de­construcción­puede­causar­una­exposición­a­niveles­de­CO,­CO2­y­NO2­ considerados­como­peligrosos­para­la­salud­y­potencialmente­letales.­ •­No­lo­utilice­en­áreas­sin­ventilación. •­Conozca­los­signos­de­envenenamiento­por­CO­y­CO2.­ •­Dolor­de­cabeza,­picazón­en­los­ojos­ •­Mareo,­desorientación­ •­Dificultad­para­respirar,­sentirse­sofocado­ •­Se­debe­proporcionar­aire­de­ventilación­exterior­adecuado­(OSHA­29­CFR­1926.57)­como­para­mantener­la­combustión­y­ una­calidad­de­aire­aceptable­de­acuerdo­con­la­norma­OSHA­29­CFR­Parte­1926.154,­con­los­requisitos­de­seguridad­para­ dispositivos­y­equipos­de­calefacción­temporarios­y­portátiles­utilizados­en­la­industria­de­la­construcción­(ANSI­A10.10)­o­ con­las­normas­de­instalación­para­gas­natural­y­propano­(CSA­B149.1).­­ •­Controle­periódicamente­los­niveles­de­CO,­CO2­y­NO2­presentes­en­el­lugar­de­la­construcción­(como­mínimo,­al­ principio­del­turno­de­trabajo­y­luego­de­4­horas).­ •­Proporcione­aire­de­ventilación­exterior,­ya­sea­de­forma­natural­o­mecánica,­como­sea­necesario­para­mantener­una­...
  • Página 28: Instrucciones De Uso

    ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! ¡NUNCA DEJE EL CALENTADOR DESATENDIDO MIENTRAS SE QUEMA! INSTRUCCIONES DE USO Modelo­# Y MANUAL DEL USUARIO MH35FA LEA CUIDADOSAMENTE LAS INSTRUCCIONES: lea­y­siga­todas­las­instrucciones.­Consérvelas­en­ un­lugar­seguro­para­futura­referencia.­No­permita­que­nadie­que­no­haya­leído­estas­instrucciones­ arme,­encienda,­ajuste­o­use­el­calentador. ADVERTENCIA: USE­SOLAMENTE­REPUESTOS­DEL­FABRICANTE.­EL­USO­DE­CUALQUIER­OTRA­PIEZA­...

Tabla de contenido