Idiomas disponibles

  • MEXICANO, página 43

6. Ex-data

6.1. ATEX

EU type examination certificate :
Ex-marking:
Ambient temperature:
Approved for Zone 2,1 and 0, device group II, explosion group IIC,
temperature class T4.
Approved for zone 22, 21 and 20, device group II, explosion group IIIC,
maximum Temperature 130°C.

6.2. IECEx

IECEx Certificate of Conformity no.:
Ex-marking:
Ambient temperature:
Approved for Zone 2, 1 and 0, device group II, explosion group IIC,
temperature class T4.
Approved for zone 22, 21 and 20, device group II, explosion group IIIC,
maximum Temperature 130°C.

7. Technical data

Ambient temperature:
Storage temperature:
Battery / power supply:
Lamp:
Luminosity:
Luminous flux:
Operating time:
6
EPS 16 ATEX 1 170 X
† II 1 G Ex ia op is IIC T4 Ga IP65
† II 1 D Ex ia IIIC T130° Da IP65
-20°C ≤ Ta ≤ +50°C
IECEx EPS 16.0074X
Ex ia op is IIC T4 Ga IP65
Ex ia IIIC T130°C Da IP65
-20°C ≤ Ta ≤ +50°C
-20°C ≤ Ta ≤ +50°C
-30°C ... +60°C (without batteries)
3 x LR14 (see table with approved batteries)
1 high-performance LED (3 watt)
5000 lx (at a distance of 1 m)
204 lumens
> 48 hours (continuous operation)