We reserve the right to make changes and technical improvements.
•
This documentation was compiled to the best of our knowledge, but we cannot rule out the possibility of
errors. We shall accept no liability for this.
•
If there are deviations in the content of foreign language versions of documentation, the original German
version shall apply in the event of any doubt.
•
Please ensure that you do not crush the cables during installation and that they are not installed under strain
in the door.
aSSembly information.
The batteries are already installed when supplied!
•
When installing the SmartHandle 3062, ensure that there are no low-frequency sources of interference in
the surrounding area.
•
SmartHandles should be fitted at least 0.5 m away from other SmartHandles and 1.5 m away from
SmartRelais and/or activation units.
•
The SmartHandle handle must be flush with the door. Assembly must be performed properly to guarantee
the product's stability and durability.
•
Do not strike parts of the SmartHandle during assembly.
•
Both of the guards are locked with a clip fixture. They may only be removed using the SimonsVoss assembly
tool.
•
SnapIn: with fire-retardant doors (9 mm square) care must be taken to ensure that the profile cylinder cover
supplied is slid onto the SnapIn mechanism for the inner fitting.
•
The WP version must always be used if the outside of the SmartHandle is likely to come into contact with
moisture etc.
•
Programme SmartHandles before installing them! SmartHandles G1 are supplied in "storage mode" ex works
and cannot be actuated with a transponder before initial programming!
•
It can be rather difficult to install the SmartHandle on mortise locks with clamping nuts. Under no
circumstances should you machine the clamping nut (e.g. with a file or similar tool), otherwise the handle will
lose its custom-fit guide.
aSSembly Smart Handle.
1. Optional: remove handles / collars / fittings etc. fitted to the door.
2. Optional: fasten mortise lock in door
3. The SmartHandle is supplied in a partly assembled state. For disassembly, please refer to the "Disassembly"
section and perform steps 7-11.
4. Turn to move the handle on the outer fitting into the appropriate horizontal position for a DIN left or DIN right
door. Ensure that the adapter is secure, such that the handle is fixed (see figure 1):
a.
Move handle into appropriate horizontal position
b.
Fit adapter in outer fitting. Slide it as far as possible into the corresponding recess. The projection
must always be facing downwards in the 6 o'clock position.
c.
Secure adapter with circlip using circlip pliers
5. Optional: if you're using a SmartHandle for British Oval mortise locks, slide adapter provided on to snap-in
mechanism of inner fitting.
6. Optional: For a lock with an 8.5 mm or 10 mm square, slide the appropriate sleeve (8 mm -> 8.5 mm or
8 mm -> 10 mm) from inside through the latch opening of the mortise lock.
7.
Optional: with fire-retardant doors (9 mm square) care must be taken to ensure that the profile cylinder cover
supplied is slid onto the SnapIn mechanism for the inner fitting.
8. Slide 3-pin cable of inner fitting into snap-in mechanism. These parts are then protected from external
influences during assembly (figure 2).
9. Assemble inner fitting on inside of door. Fasten inner fitting to door by sliding square end through latch
holder and snap-in mechanism through Euro profile cylinder/Swiss Round/British Oval opening of mortise
lock at the same time.
10. Slide inner fitting through until it is flush with the door.
11. Remove cables from snap-in mechanism such that they are free from the door and are not damaged (fig. 3).
12. Assemble outer fitting from outside of door. At the same time, slide latch of outer fitting on to square end and
snap-in mechanism of outer fitting into snap-in of inner fitting.
13. Slide outer fitting until it is approx. 1 cm away from the door.
11