11. TROUBLESHOOTING

1. The pump is not primed
2. The pump releases only a small flow of water 5. The motor is making a noise but will not start
3. The pump makes a noise
1
2
3
4
KIVU PUMP
- ASTRALPOOL
5
6
CAUSES
Air entering the suction pipe
Filter cap badly sealed
Inverted motor turning
Wrong voltage
Pre-filter blocked
Load loss in the installation
Pump incorrectly secured
Motor blocked
Increased temperature in the terminal
box due to electric arc
The thermal protection trips
Incorrect terminal box connections
4. The pump will not start
6. The motor is stopped
Check the condition of connections and seals on the suction pipe
Clean the filter cap and check the condition of the rubber seal
Invert 2 power phases
Check the voltage on the characteristics plate and that of the
mains
Clean the filter
Prevent parts from causing load loss wherever possible
Secure the pump correctly
Remove the motor and contact the technical service
Check the terminal box connections
Connect the cables correctly to the terminal boxes
Tighten the cable correctly to the terminal / Adapt the size of the
cable connection to the terminal box
SOLUTIONS
11