Periodic checks

CHECK
Cleaning the dirty water tank
Cleaning the suction floats
Cleaning the water/detergent tank filter
Cleaning the suction filter
Cleaning the front squeegee suction hose
Cleaning the rear squeegee suction hose
Cleaning the diverter valve
Cleaning the squeegee blades
Checking squeegee blade wear
Checking brush wear
[B] Battery powered model.
[C] Mains powered model.
PROBLEM
Machine not working.
Brush not rotating.
Brush motor not starting easily.
Machine not scrubbing uniformly.
Detergent solution not reaching brush.
Suction motor not working.

TROUBLESHOOTING

CAUSE
[B] Battery low or flat.
[C] Plug disconnected.
[B-C] Main switch not activated.
[B-C] Brush control button not
depressed.
[B-C] Brush control lever not activated.
[B-C] Machine is working with a dry
brush on a particularly rough floor.
[B-C] Brush or pad worn.
[B-C] Detergent tank empty
[B-C] Water/detergent tank filter dirty.
[B-C] Blockage in hose delivering
detergent solution to brush.
[B-C] Suction control button not
depressed.
EN
X
X
X
X
X
X
X
X
X
REMEDY
[B] Recharge battery
[C] Connect plug to mains socket
[B-C] Press main switch.
[B-C] Press brush control button.
[B-C] Operate brush control lever.
Increase the quantity of detergent.
[B-C] Replace brush.
[B-C] Fill detergent tank.
[B-C] Clean filter.
[B-C] Remove blockage.
[B-C] Press suction control button.
X